Showing posts with label Physics concepts. Show all posts
Showing posts with label Physics concepts. Show all posts

Tuesday, 6 October 2015

Thermoelectric Effect



The thermoelectric effect is the direct conversion of temperature differences to electric voltage and vice versa. A thermoelectric device creates voltage when there is a different temperature on each side. Conversely, when a voltage is applied to it, it creates a temperature difference. At the atomic scale, an applied temperature gradient causes charge carriers in the material to diffuse from the hot side to the cold side.
This effect can be used to generate electricity, measure temperature or change the temperature of objects. Because the direction of heating and cooling is determined by the polarity of the applied voltage, thermoelectric devices can be used as temperature controllers.
The term "thermoelectric effect" encompasses three separately identified effects:
The Seebeck effect,
Peltier effect, and
Thomson effect.

1. The Seebeck effect
The Seebeck effect is the conversion of temperature differences directly into electricity and is named after the Baltic German physicist Thomas Johann Seebeck. Seebeck, in 1821, discovered that a compass needle would be deflected by a closed loop formed by two different metals joined in two places, with a temperature difference between the junctions. This was because the metals responded to the temperature difference in different ways, creating a current loop and a magnetic field. Seebeck did not recognize there was an electric current involved, so he called the phenomenon the thermomagnetic effect. Danish physicist Hans Christian Oersted rectified the mistake and coined the term "thermoelectricity".
2. The Peltier effect
The Peltier effect is the presence of heating or cooling at an electrified junction of two different conductors and is named after French physicist Jean Charles Athanase Peltier, who discovered it in 1834. When a current is made to flow through a junction between two conductors A and B, heat may be generated (or removed) at the junction.
3. Thomson effect
In many materials, the Seebeck coefficient is not constant in temperature, and so a spatial gradient in temperature can result in a gradient in the Seebeck coefficient. If a current is driven through this gradient then a continuous version of the Peltier effect will occur. This Thomson effect was predicted and subsequently observed by Lord Kelvin in 1851. It describes the heating or cooling of a current-carrying conductor with a temperature gradient.


Applications

Thermoelectric generator

The Seebeck effect is used in thermoelectric generators, which function like heat engines, but are less bulky, have no moving parts, and are typically more expensive and less efficient. They have a use in power plants for converting waste heat into additional electrical power (a form of energy recycling) and in automobiles as automotive thermoelectric generators (ATGs) for increasing fuel efficiency. Space probes often use radioisotope thermoelectric generators with the same mechanism but using radioisotopes to generate the required heat difference.


Peltier effect: Thermoelectric cooling
The Peltier effect can be used to create a refrigerator that is compact and has no circulating fluid or moving parts. Such refrigerators are useful in applications where their advantages outweigh the disadvantage of their very low efficiency.

Temperature measurement:
Thermocouples and thermopiles are devices that use the Seebeck effect to measure the temperature difference between two objects, one connected to a voltmeter and the other to the probe. The temperature of the voltmeter, and hence that of the material being measured by the probe, can be measured separately using cold junction compensation techniques.

Thermal cyclers for polymerase chain reaction

The Peltier effect is used by many thermal cyclers, laboratory devices used to amplify DNA by the polymerase chain reaction (PCR). PCR requires the cyclic heating and cooling of samples to specified temperatures. The inclusion of many thermocouples in a small space enables many samples to be amplified in parallel.